PRODUCT DESCRIPTION
This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select between the internally mounted GM detector with an exposure range of 0–20 mSv/h (0–2000 mR/hr) or an external GM or scintillator detector of choice (see table below).
The aluminum cast instrument housing, with its separate battery compartment and accompanying metal handle, offer an industrial robustness and quality that promote long-lasting protection and instrument life. The front-panel controls include a rotary switch for selecting the five-decade range and instrument shut-off, an audio on/off switch, a fast/slow response switch, a high voltage display button, and a battery test button.
The analog meter face comes in a variety of options to support the measurement units and ranges for the additional external detector selected. A one meter (39 in.) straight type detector cable with "C" style connector is included in the price of the instrument.
FEATURES
-
Low Price
-
Rugged
-
5-Range Analog Ratemeter
-
Operates Two Detectors
- Built-in Internal GM Detector (0–2000 mR/hr)
- External GM or Scintillator Detector
SPECIFICATIONS
-
APPLICATION: alpha, beta, and gamma surveying
-
COMPATIBLE DETECTORS: GM, scintillation
-
DETECTOR CHANNELS: x0.1 through x100 range settings readout the external detector channel, x1000 reads out the internal GM detector
-
EXTERNAL DETECTOR: any GM or scintillator operating on 900 VDC
-
INTERNAL DETECTOR: energy compensated GM, 0–20 mSv/h (0–2000 mR/hr), used with x1000 scale only, sensitivity: 200 cpm/mR/hr
-
ENERGY RESPONSE: within 15% of true value between 60 keV-3 MeV (internal detector only)
-
LINEARITY: reading within 10% of true value with detector connected
-
HIGH VOLTAGE: 900 volts
THRESHOLD: -40 mV to 10 mV
CONNECTOR: series "C" -
METER: 6.4 cm (2.5 in.) arc, 1 mA analog type
-
METER DIAL: typically 0 to 2 mR/hr and cpm, BAT TEST
-
CONTROLS:
- Rotary Selector Switch: switches instrument to Off or ranges: x0.1, x1, x10, x100 x1000
- Response Switch: toggles between FAST (4 seconds) or SLOW (22 seconds) from 10% to 90% of final reading
- Reset Push Button: to zero meter
- Battery Push Button: checks battery status
- Audio Switch: for audio on/off, built-in unimorph speaker, greater than 60 dB at 0.6 meters (2 ft)
-
POWER: 2 each "D" cell batteries (housed in an externally accessible sealed compartment)
-
BATTERY LIFE: typically greater than 2000 hrs (battery condition can be checked on meter)
-
CONSTRUCTION: cast and drawn aluminum with beige powder coat
-
TEMPERATURE RANGE: -20 to 50 °C (-4 to 122 °F)
-
RELATIVE HUMIDITY: < 95%
-
SIZE: 16.5 x 8.9 x 21.6 cm (6.5 x 3.5 x 8.5 in.) (H x W x D)
-
WEIGHT: 1.6 kg (3.5 lb), including batteries
ITEM NUMBERS
|
5250-0114 |
Ludlum 14C with Pancake Probe |

together2s.com@gmail.com















Diễn tập ứng phó sự cố bức xạ và hạt nhân trên địa bàn thành phố Huế
Chuyển đổi số trong lĩnh vực năng lượng nguyên tử: Kinh nghiệm quốc tế và gợi ý cho Việt Nam
Tái khởi động dự án điện hạt nhân: Công nghệ nào cho Việt Nam
Hậu Giang: Khai trương nhà máy chiếu xạ nông sản xuất khẩu công suất 1.000 tấn/ngày đêm
Hơn 800 nguồn bức xạ được bảo vệ nghiêm ngặt
Tiếp tục hoàn thiện, nâng cao vai trò và hiệu quả quản lý nhà nước về ATBXHN
Kiên Giang: Nguyên nhân hệ thống thiết bị Cyclotron hơn 10 năm chưa lắp đặt xong
Sở Y tế Kiên Giang dự kiến mời chuyên gia hoàn thành đánh giá hệ thống cyclotron trong quý 3/2024; khắc phục bổ sung ...
Việt Nam sẽ xây dựng lò phản ứng hạt nhân mới phục vụ phát triển kinh tế - xã hội
Vô tư nhặt "vật thể lạ" lên xem, người đàn ông Trung Quốc tàn tật cả đời.
Thủy lên mạng xã hội tìm mua các thiết bị phục vụ việc đánh bạc bịp để bán lại cho những người có nhu ...
Cách đây 20 năm (9/2003-9/2023), Hội đồng Thống đốc Cơ quan Năng lượng nguyên tử quốc tế (IAEA) đã phê duyệt Bộ quy tắc ...
Cá ở Nhật nhiễm phóng xạ cao gấp 180 lần giới hạn cho phép
Lo ngại của người dân khu vực trước khi Nhật Bản xả nước nhiễm phóng xạ
Công ty Nhôm Ðắk Nông tập trung kiểm soát nguồn bức xạ
Ứng dụng phương pháp nhiệt phát quang trong đo liều bức xạ
(Chinhphu.vn) - Đây là đề xuất của Bộ Tài chính tại dự thảo Thông tư sửa đổi, bổ sung một số điều của Thông ...
Dự thảo Nghị định sửa đổi, bổ sung một số điều của các nghị định về xử phạt vi phạm hành chính (VPHC) trong ...